top of page

Products

Filter by Fields
Filter by Applications (Filter)
Filter by Mounting
Filter by Measurements (Filter)

Number of selected Products: 

20

MLSS / (activated) sludge concentration (Tentacle version, Submersible)
OTE-MLSA

MLSS / (activated) sludge concentration (Tentacle version, Submersible)

Sensor for Mixed Liquor Suspended Solids (MLSS) 

Factory callibrated sensor with modbus interface.

MLSS / (activated) sludge concentration (Inline)
OTU-MLSA

MLSS / (activated) sludge concentration (Inline)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

Suspended Sediment Concentration (SSC) (Submersible)
OTE-SEDA

Suspended Sediment Concentration (SSC) (Submersible)

Suspended Sediment Concentration (SSC) sensors, using a novel Olpas-proprietary 3-8 Mhz Accoustic Backscattering measurement technology for an exceptional wide coverage of particle sizes for its concentration measurement.

Factory calibrated sensor with exceptional drift-resistant and very few maintenance.

Suspended Sediment Concentration (SSC) (inline)
OTU-SEDA

Suspended Sediment Concentration (SSC) (inline)

Inline SSC (Suspended Sediment Concentration) sensors, using the Olpas-proprietary 3-8 Mhz Accoustic Backscattering measurement technology for a wide coverage of particle sizes for its concentration measurement.  

Factory calibrated sensor with exceptional drift-resistant and very few maintenance.  Sensor is easy to install and to maintain with the hot-tap mounting support. 

Sludge concentration/TSS (Tentacle version, Submersible)
OTE-SDXA

Sludge concentration/TSS (Tentacle version, Submersible)

Sensor for Sludge Concentrations 0-100 g/L (actived) sludge. 

Factory callibrated sensor with modbus interface.

TSS concentration (Inline mounting)
OTU-TSSB

TSS concentration (Inline mounting)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS concentration in challenging environments
OTE-TSSC

TSS concentration in challenging environments

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

TSS Low Concentration (Inline)
OTU-TSSD

TSS Low Concentration (Inline)

Low concentration TSS measurement (0 - 2.000 mg/L). Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS Concentration and Local Flow Velocity
OTN-TSSC

TSS Concentration and Local Flow Velocity

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

Dry Solids (%DS) measurement in Iron water / Iron sludge (Inline mounting)
OTU-IWAA

Dry Solids (%DS) measurement in Iron water / Iron sludge (Inline mounting)

Measurement of dry matter (dry solids, DS) in iron water, iron sludge, ferric (hydr)oxide. 


Dry Solids (%DS) measurement in Iron water / Iron sludge (Tentacle version, Submersible)
OTE-IWAA

Dry Solids (%DS) measurement in Iron water / Iron sludge (Tentacle version, Submersible)

Measurement of dry matter (Dry Solids, DS) in iron water / iron sludge / iron oxide sludge / ferric sludge / slurries.


Polymer Concentration Measurement (PCM) - Membrane safeguarding (Inline)
OTU-PCMB

Polymer Concentration Measurement (PCM) - Membrane safeguarding (Inline)

Measuring Polyelektrolyte (PE)/Polymer/Flocculant/Coagulant in low concentrations, as part of safeguarding and monitoring tool for membranes.  Easy installation and maintenance with Hot-Tap retractable.

Sludge Concentration (Inline mounting, hot-tap transducer)
OTU-SDXA

Sludge Concentration (Inline mounting, hot-tap transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS in dewatering centrate (with centrate pump and flowcell)
OTD-SDPB

TSS in dewatering centrate (with centrate pump and flowcell)

An easy to install end-to-end measurement solution with limited impact of air-bubbles and exceptional fouling resistance thanks to ultrasound measurement technology.  For measuring TSS in concentrations from 0 - 2.000 mg/L. 

The device consists of a sample grabber (centrate pump) and flow-cell.

TSS in dewatering centrate (inline mounting, hot-tap transducer)
OTU-SDXB

TSS in dewatering centrate (inline mounting, hot-tap transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

Polymer Concentration Measurement (PCM) (High concentrations, Inline)
OTU-PCMA

Polymer Concentration Measurement (PCM) (High concentrations, Inline)

Measuring high concentrations of PE/Polymer flocculant in the PE dissolution process (from powder), PE emulsion, PE dilution and activation.  Easy installation and maintenance with Hot-Tap retractable.

Residual Polymers in dewatering centrate (with centrate pump and flowcell)
OTD-SDPC

Residual Polymers in dewatering centrate (with centrate pump and flowcell)

An easy to install end-to-end measurement solution with limited impact of air-bubbles and exceptional fouling resistance thanks to ultrasound measurement technology.  For measuring polymer concentrations. 

The device consists of a sample grabber (centrate pump) and flow-cell.

Sludge Cake Concentration (Inline mounting, SS316 transducer)
OTU-SDXD

Sludge Cake Concentration (Inline mounting, SS316 transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

Sludge Cake Concentration - Grabbing Solution and Sensor
OTD-SDWE

Sludge Cake Concentration - Grabbing Solution and Sensor

The Olpas sludge concentration measurement system consists of a dataprocessor and ultrasound transducer, with a sample grabber.  The system is capable of measuring sludge in concentrations from 0 - 40 %DS. 

The Olpas ultrasound technology provides a fouling-resistant measurement of the sludge concentration, independent of sludge type or morphology.

Solids Concentration Measurement - Through Pipe (Clamp-on) [TRL-7]
OTD-THRC

Solids Concentration Measurement - Through Pipe (Clamp-on) [TRL-7]

Clamp-on sensor for measurement through pipe.

bottom of page