top of page

Measurements we cover

MLSS - Mixed Liquor Suspended Solids

MLSS - Mixed Liquor Suspended Solids

Mixed Liquor Suspended Solids (MLSS) is the concentration of suspended solids in an aeration tank during the activated sludge process, which is a key parameter to monitor the active biomass.

Polymer (PE) and coagulant concentration

Polymer (PE) and coagulant concentration

Detecting polymer levels helps safeguarding membranes, control overdosing or underdosing in sludge settling and dewatering, and minimizing operational costs or environmental impacts.

Dry solids in Iron Sludge and Iron Slurry

Dry solids in Iron Sludge and Iron Slurry

Measuring Dry Solids (dry matter) in iron sludge / iron water for mining and water supply (drink water production) or industrial water treatment

TSS - Total Suspended Solids

TSS - Total Suspended Solids

Total Suspended Solids (TSS) is the portion of not dissolved solid particles suspended in water.
This includes organic and inorganic materials, such as silt, decaying matter, industrial wastes, and sewage.

 Sludge Concentration (Solids concentration in sludge)

Sludge Concentration (Solids concentration in sludge)

The Olpas Sludge Concentration sensors offers a cost-effective measurement with maintenance intervals that are four times longer compared to optical sensors.

Dry Solids (%DS) in sludge cake

Dry Solids (%DS) in sludge cake

Dry Solids measurement for Dry Cake, measuring sludge cake density in concentrations from 10 - 40 %DS. There are inline sensors available, and sensors with a sample-grabbing device.

TSS in dewatering centrate/filtrate

TSS in dewatering centrate/filtrate

Measuring Total Suspended Solids (TSS) in dewatering centrate is a challenging task, but the innovative OLPAS ultrasound measurement technology makes it achievable, providing valuable insights into the dewatering process's effectiveness.

Residual Polymer  (PE) in centrate/filtrate

Residual Polymer (PE) in centrate/filtrate

Monitoring residual polymers in centrate is crucial for optimizing the dewatering process. The Olpas sensor provides a reliable measurement of this hard-to-measure parameter, even in dewatering centrate.

Polymer (PE) concentration in low concentrations

Polymer (PE) concentration in low concentrations

Polymers are aded during the watertreatment process to enhance the removal of suspended solids and other contaminants. Olpas sensors help monitoring polymer-concentrations during the process and even in effluent.

High Solids Concentration Measurement

High Solids Concentration Measurement

Available for inline measurement (with the sensor in direct contact with the fluid or paste) and as a clamp-on (for measurement through the pipe).
For high solids concentrations up to 60 %DS.

RAS - Return Activated Sludge

RAS - Return Activated Sludge

RAS indicates the portion of settled activated sludge that is returned from the clarifier to the aeration tank.
Maintains a high concentration of microorganisms for effective biological treatment.

RAS - Return Activated Sludge Copy

RAS - Return Activated Sludge Copy

RAS indicates the portion of settled activated sludge that is returned from the clarifier to the aeration tank.
Maintains a high concentration of microorganisms for effective biological treatment.

bottom of page