top of page

TSS - Total Suspended Solids

Total Suspended Solids (TSS) is the portion of not dissolved solid particles suspended in water. It includes organic and inorganic materials, such as silt, decaying matter, industrial wastes, and sewage.

Olpas TSS sensors measure in ranges from 0-1000 mg/L and 0-2000 mg/L to 0-20 g/L (and many more ranges), and in challenging environments like sewers, overflows or even in dewatering centrate.

TSS - Total Suspended Solids

Applications of TSS Meaurements

  • TSS in dewatering centrate / filtrate

  • TSS in water monitoring

  • TSS in sewers, combined sewer overflows (CSOs) and stormwater

  • ...


Key features

  • A reliable drift-resistant measurement of TSS

  • Fouling resistance, also in the most challenging environments:

    • TSS measurements in sewers or overflows

    • TSS measurements in filtrate with high residual polymer load (leading to additional fouling)

  • No automated mechanical cleaning necessary

  • Low maintenance and easy cleaning


Olpas TSS sensors where optical turbidity sensors fail

Current state-of-the-art optical sensors fail to measure the concentration accurately in changing conditions, due to their dependence on the optical parameters of the centrate.

Furthermore, fouling is often present after a few days of operations (sometimes even hours when used in centrate - especially in centrate with high residual PE!).



Application: TSS in dewatering centrate / filtrate

Measuring Total Suspended Solids (TSS) in dewatering centrate is a challenging task due to the big flocks of solids and the air bubbles. The (often) high concentrations of residual PE and extreme variations in solids concentration and diameter, have an impact on the accuracy when traditional measurement technologies are used. That's why Olpas developed its end-to-end measurement, with flow-cell. Together with the innovative OLPAS ultrasound measurement technology it makes measuring TSS in centrate achievable, providing valuable insights into the dewatering process's effectiveness.

Centrate quality as an essential parameter to monitor the dewatering process, and provide feedback control


TSS in centrate gives important insight in the dewatering efficiency, but also provides quality assurance: it ensures that the quality of the separated liquid (centrate) meets the requirements before it is flow back into the WWTP for processing.


An accurate reliable measurement that swiftly follows the trend allows the control system logic to adapt the sludge flow-rate, dewatering-parameters and PE-concentration.

 


Application: TSS in sewers and storm overflows

Equipped with advanced fouling resistance and minimal sensor drift, these TSS sensors are designed for fixed installations, or can be mounted freely or within guide tubes for stability.

“Olpas watermonitoring sensors are the most economic choice when low-maintenance is required. A once-per-season maintenance action was enough, while our previous sensor required a once-per-week visit. The ROI of the Olpas sensor was less than 6 months!”

Also check these Whitepapers

Sensors for TSS - Total Suspended Solids

Number of selected sensors: 

6

TSS concentration (Inline mounting)

OTU-TSSB

TSS concentration (Inline mounting)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS concentration in challenging environments

OTE-TSSC

TSS concentration in challenging environments

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

TSS Low Concentration (Inline)

OTU-TSSD

TSS Low Concentration (Inline)

Low concentration TSS measurement (0 - 2.000 mg/L). Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS Concentration and Local Flow Velocity

OTN-TSSC

TSS Concentration and Local Flow Velocity

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

Sludge Concentration (Inline mounting, hot-tap transducer)

OTU-SDXA

Sludge Concentration (Inline mounting, hot-tap transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

TSS in dewatering centrate (with centrate pump and flowcell)

OTD-SDPB

TSS in dewatering centrate (with centrate pump and flowcell)

An easy to install end-to-end measurement solution with limited impact of air-bubbles and exceptional fouling resistance thanks to ultrasound measurement technology.  For measuring TSS in concentrations from 0 - 2.000 mg/L. 

The device consists of a sample grabber (centrate pump) and flow-cell.

bottom of page