top of page
Wastewater

Olpas sensors for water treatment are especially used for challenging measurement: high loads (ex. influent or activated sludge), with exceptional drift resistance and longer maintenance windows.

Communal (sewage / urban) wastewater has unique properties that make it difficult to measure solids concentrations (such as Total Suspended Solids (TSS), Mixed liquor suspended solids (MLSS), and sludge concentration) using conventional (optical or other) sensors. This difficulty is due to factors such as fouling, the presence of air bubbles, and struvite precipitation.


For these difficult-to-measure situations, Olpas offers a range of sensors that can accurately measure concentration levels in both water treatment and sludge processing.


Thanks to the specific characteristics of the OLPAS Technology and its sensors, currently most value is delivered on these locations in the wastewater treatment plant:

  • Influent

  • Activated sludge

  • Return activated sludge

  • Sludge dewatering

  • Polymer-concentration measurement


Olpas is constantly developing new applications. In Urban water treatment, but also in other fields. Make sure to get in touch if you have a need for a specific measurement that should be less prone to (bio)fouling and precipitation, that requires longer maintenance windows or that has not been tackeled yet succesfully using the traditional optical or microwave based measurement technologies.

Applications in this field

An Olpas Sludge Concentration sensor installed at a WWTP

Activated Sludge

Monitoring activated sludge (MLSS or RAS or TSS) is essential for controlling biological treatment, maintaining microbial health, and achieving stable and efficient organic and nutrient removal.

An Olpas Sludge Concentration sensor installed at a WWTP

Effluent

Tracking solids (TSS) or PE (Polymers) ensures regulatory compliance, protects aquatic life, and evaluates treatment performance before water is discharged to the environment.

An Olpas Sludge Concentration sensor installed at a WWTP

Centrate and Filtrate monitoring

Monitoring filtrate or centrate ensures dewatering efficiency, optimizes centrifuge/filter performance, and prevents downstream process issues caused by carryover of suspended solids or residual polymers.

Products available in this field 

Selected Products: 

17

OTE-MLSA

OTE-MLSA

MLSS / (activated) sludge concentration (Tentacle version, Submersible)

Sensor for Mixed Liquor Suspended Solids (MLSS) 

Factory callibrated sensor with modbus interface.

OTU-MLSA

OTU-MLSA

MLSS / (activated) sludge concentration (Inline)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

OTE-SDXA

OTE-SDXA

Sludge concentration/TSS (Tentacle version, Submersible)

Sensor for Sludge Concentrations 0-100 g/L (actived) sludge. 

Factory callibrated sensor with modbus interface.

OTU-TSSB

OTU-TSSB

TSS concentration (Inline mounting)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

OTE-TSSC

OTE-TSSC

TSS concentration in challenging environments

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

OTN-TSSC

OTN-TSSC

TSS Concentration and Local Flow Velocity

Olpas TSS sensors are pre-calibrated, drift-resistant and required very few maintenance; thanks to an industry leading fouling resistance and minimal sensor drift. 

OTU-IWAA

OTU-IWAA

Dry Solids (%DS) measurement in Iron water / Iron sludge (Inline mounting)

Measurement of dry matter (dry solids, DS) in iron water, iron sludge, ferric (hydr)oxide. 


OTE-IWAA

OTE-IWAA

Dry Solids (%DS) measurement in Iron water / Iron sludge (Tentacle version, Submersible)

Measurement of dry matter (Dry Solids, DS) in iron water / iron sludge / iron oxide sludge / ferric sludge / slurries.


OTU-PCMB

OTU-PCMB

Polymer Concentration Measurement (PCM) - Membrane safeguarding (Inline)

Measuring Polyelektrolyte (PE)/Polymer/Flocculant/Coagulant in low concentrations, as part of safeguarding and monitoring tool for membranes.  Easy installation and maintenance with Hot-Tap retractable.

OTU-SDXA

OTU-SDXA

Sludge Concentration (Inline mounting, hot-tap transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

OTD-SDPB

OTD-SDPB

TSS in dewatering centrate (with centrate pump and flowcell)

An easy to install end-to-end measurement solution with limited impact of air-bubbles and exceptional fouling resistance thanks to ultrasound measurement technology.  For measuring TSS in concentrations from 0 - 2.000 mg/L. 

The device consists of a sample grabber (centrate pump) and flow-cell.

OTU-SDXB

OTU-SDXB

TSS in dewatering centrate (inline mounting, hot-tap transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

OTU-PCMA

OTU-PCMA

Polymer Concentration Measurement (PCM) (High concentrations, Inline)

Measuring high concentrations of PE/Polymer flocculant in the PE dissolution process (from powder), PE emulsion, PE dilution and activation.  Easy installation and maintenance with Hot-Tap retractable.

OTD-SDPC

OTD-SDPC

Residual Polymers in dewatering centrate (with centrate pump and flowcell)

An easy to install end-to-end measurement solution with limited impact of air-bubbles and exceptional fouling resistance thanks to ultrasound measurement technology.  For measuring polymer concentrations. 

The device consists of a sample grabber (centrate pump) and flow-cell.

OTU-SDXD

OTU-SDXD

Sludge Cake Concentration (Inline mounting, SS316 transducer)

Factory callibrated sensor with Modbus interface. 

Extended transducer for easy installation and maintenance with Hot-Tap retractable.

OTD-SDWE

OTD-SDWE

Sludge Cake Concentration - Grabbing Solution and Sensor

The Olpas sludge concentration measurement system consists of a dataprocessor and ultrasound transducer, with a sample grabber.  The system is capable of measuring sludge in concentrations from 0 - 40 %DS. 

The Olpas ultrasound technology provides a fouling-resistant measurement of the sludge concentration, independent of sludge type or morphology.

OTD-THRC

OTD-THRC

Solids Concentration Measurement - Through Pipe (Clamp-on) [TRL-7]

Clamp-on sensor for measurement through pipe.

bottom of page