Water monitoring of Sediment load

OTD-SEDA

OTD-SEDA-001

Sonde, Sediments: 0 - 50 g/L

Sonde, Sediments: 0 - 50 g/L

Fixed mounting

The fixed mounting of the sensor is done using two hanging brackets (M10). The use of a stainless steel bracket with rubber lining is necessary to protect the sensor against corrosion and mechanical damage.

Suspension

A flexible installation can be achieved by suspending the sensor from the provided bracket. Refer to section 10 for the correct
components to perform this. Olpas prefers suspension using a stainless steel chain. This can be done either as a free-hanging
installation (no restriction on lateral movement of the sensor) or by using a standpipe (restricting the lateral freedom of the
sensor). Both solutions are ideal for easily removing the sensor for routine or preventive maintenance.


Water Level
The Olpas Tentacle is designed to operate fully or partially submerged in water at all times. Contact with water on the ultrasonic
window is necessary to perform a measurement. Temporary drying of the sensor will not cause damage, and the sensor will
automatically resume operation upon contact with water. However, frequent drying of the ultrasonic window will shorten the
maintenance interval due to strong adhesion of dirt residues.

All product variations

Water monitoring of TSS concentration
CUSTOM
Custom solution possible
Water monitoring of Sediment load
CUSTOM
Custom solutions possible
MLSS / (activated) sludge concentration
OTD-MLSA-002
MLSS/ (activated) sludge concentration: 0 - 10 g/L
MLSS / (activated) sludge concentration
OTD-MLSA-003
MLSS/ (activated) sludge concentration: 0 - 20 g/L
Sludge Concentration
OTD-SDWA-00X
TSS (Sludge concentration) in sludge: 0 - 10% solids
TSS in dewatering centrate
OTD-SDWB-00X
TSS in centrate
Polymer concentration in centrate
OTD-SDWC-00X
Polymer concentration in centrate
Sludge cake
OTD-SDWD-00X
Dry Solids in Sludge Cake: 0 - 40% DS
Water monitoring of Sediment load
OTD-SEDA-001
Sonde, Sediments: 0 - 50 g/L
TSS concentration
OTD-TSSA-001
TSS concentration: 0 - 100 mg/L
TSS concentration
OTD-TSSA-002
TSS concentration: 0 - 500 mg/L
TSS concentration
OTD-TSSA-003
TSS concentration: 0 - 1.000 mg/L
TSS concentration
OTD-TSSA-004
TSS concentration: 0 - 10.000 mg/L
Water monitoring of TSS concentration
OTD-TSSC-001
Sonde, TSS concentration: 0 - 2 g/L
Water monitoring of TSS concentration
OTD-TSSC-002
Sonde, TSS concentration: 0 - 4 g/L
Water monitoring of TSS concentration
OTD-TSSC-003
Sonde, TSS concentration: 0 - 6 g/L
Water monitoring of TSS concentration
OTD-TSSD-001
Sonde with extended sensor tube, TSS concentration: 0 - 2 g/L
Water monitoring of TSS concentration
OTD-TSSD-002
Sonde with extended sensor tube, TSS concentration: 0 - 4 g/L
Water monitoring of TSS concentration
OTD-TSSD-003
Sonde with extended sensor tube, TSS concentration: 0 - 6 g/L

Didn't find what you're looking for ? 
With our versatile OLPAS Technology, we can build a tailor made sensor optimised for your application. 

bottom of page