Sludge Cake Concentration - Grabbing Solution and Sensor

OTD-SDWE

OTD-SDWE

Sludge Cake Concentration - Grabbing Solution and Sensor

The Olpas sludge concentration measurement system consists of a dataprocessor and ultrasound transducer, with a sample grabber.  The system is capable of measuring sludge in concentrations from 0 - 40 %DS. 

The Olpas ultrasound technology provides a fouling-resistant measurement of the sludge concentration, independent of sludge type or morphology.

Download Datasheet
Sludge Cake Concentration - Grabbing Solution and Sensor

Product variations

More information about this product

Key Features

Measurement Principle:

Ultrasound energy transfer


Independence/insensitive:

Not impacted by granula nature

No removal of air pockets needed

No impact of sludge temperature fluctuation (within the range of 0-40C) 

No impact of changes of fluid colour and fluid velocity


The measurement system mounted on a purpose-built auger sampler for sludge cake. It is designed for collecting representative samples of sludge cake in various waste management and environmental applications. 

It consists of a helical screw, or auger, that is mechanically driven to capture samples falling on the top of the auger. The auger sampler helps ensure that the collected material reflects the average composition of the sludge, accounting for variations in moisture, density, and content.


The auger screw compresses the sample and transports it to the measurement cell containing the Olpas ultrasonic transducer.